- COPPER RODS
- BUSBARS
- BARE ANNEALED COPPER WIRES
- TINNED ANNEALED COPPER WIRES
- FINE COPPER WIRES
- SUPER FINE COPPER WIRES
- BUNCHED COPPER
- PVC CABLES
- C0NTINUOUS CAST COPPER ROD
- COPPER STRIP AND PREMIUM ROD
- TPC COVERED COPPER CONDUCTOR
- FINE WIRE COPPER (BARE AND TINNED)
- COPPER CONDUCTOR
- GOPALAN WIRES AND CABLES
- SUPER FINE WIRE – BARE AND TINNED
GOPALAN WIRES & CABLES — PVC CABLES
Durable, versatile wiring solutions made from pure copper (99.97%), hence providing low resistance and high conductivity. All the specifications are attached in the tables below.
Salient Features (FR and FR-LSH)
- Good Flame Retardant Properties
- Excellent resistance to moisture, abrasion, grease, oil
- Long Life
- Excellent mechanical & electrical properties
- Steam and boiling water resistant
Salient Features (ZHFR)
- Zero Halogens and Gas Evolution
- Non-corrosive and non-toxic insulation
- High temperature resistant insulation
- Excellent resistance to abrasion, grease, oil
- Long Life
Cable Standard: Generally conforms to IS 694:2010.
Standard Packing: Coils 90m, 100m, 180m and 360m.
Conductor: Annealed flexible bare copper (Class 2 and Class 5 as per IS 8130:2013).
Insulation: PVC FR, FRLS, HRFR, ZHFR.
Colour Options: Red, Yellow, Blue, Black, Brown, Grey, Orange, White, Green, or customized.
Application: Fixed installation in conduits and under plaster, for appliance wiring & distribution stations. Used for wiring in conduits & building wiring.
Technical Data
| S.NO. | DETAILS | AS PER IS : 694: 2010 | |
|---|---|---|---|
| PVC - FR | FRLS (FR-LSH) | ||
| 1 | Working Voltage | 1100 V | 1100 V |
| 2 | Operating Temp | -15°C to +70°C | -15°C to +70°C |
| 3 | Short Circuit Temp | 160°C | 160°C |
| 4 | Test Voltage | 3 KV for 5 mins | 3 KV for 5 mins |
| 5 | Oxygen Index | >29% | >29% |
| 6 | Temperature Index | >250°C | >250°C |
| 7 | Smoke Density | - | <60% |
| 8 | Halogen / Acid Gas Emission | - | <20 % by wt |
| 9 | Flammability | IS 10810-53 | IS 10810-53 |
| 10 | Shrinkage | <4% | <4% |
| 11 | Heat shock | No cracks at 150°C for 1 hour | No cracks at 150°C for 1 hour |
| 12 | Persulphate Test (Tinned wires) | Mass of copper dissolved < 0.1 mg/cm² | |
Single Core FR PVC Insulated Cable (IS 694:2010)
| Single Core FR PVC Insulated Unsheathed Cable of Voltage Grade 1100V Conforming to IS 694 - 2010 | |||||
|---|---|---|---|---|---|
| SIZE (Sq.mm) | NO. OF WIRE / WIRE DIA OF CONDUCTOR (max) (mm) |
NOMINAL INSULATION THICKNESS (mm) |
NOMINAL OVERALL CABLE DIAMETER (mm) |
MAX. DC RESISTANCE AT 20°C (OHMS/KM) |
* CURRENT CARRYING CAPACITY IN AMPS |
| 0.750 | 11/.31 | 0.60 | 2.30 | 24.50 | 8.5 |
| 1.0 | 14/0.31 | 0.60 | 2.80 | 18.10 | 12.0 |
| 1.50 | 22/0.31 | 0.60 | 3.10 | 12.10 | 16.0 |
| 2.50 | 36/0.31 | 0.70 | 3.80 | 7.41 | 22.0 |
| 4.0 | 56/0.31 | 0.80 | 4.40 | 4.61 | 29.0 |
| 6.0 | 84/0.31 | 0.80 | 5.20 | 3.08 | 37.0 |
| 10.0 | 7/1.35 | 1.00 | 6.80 | 1.83 | 49.0 |
| 16.0 | 7/1.72 | 1.00 | 7.20 | 1.15 | 76.0 |
| **Ambient temperature 40°C | ***Max. Operating temperature 70°C | |||||
Single Core FR-LSH PVC Insulated Cable (IS 694:2010)
| Single Core FR-LS(H) PVC Insulated Unsheathed Cable of Voltage Grade 1100V Conforming to IS 694 - 2010 | |||||
|---|---|---|---|---|---|
| SIZE (Sq.mm) | NO. OF WIRES / WIRE DIA OF CONDUCTOR (MAX) (mm) |
NOMINAL INSULATION THICKNESS (mm) |
NOMINAL OVERALL CABLE DIAMETER (mm) |
MAX. DC RESISTANCE AT 20°C (OHMS/KM) |
* CURRENT CARRYING CAPACITY IN AMPS |
| FRLS | |||||
| 0.750 | 24/0.21 | 0.60 | 2.30 | 26.00 | 8.5 |
| 1.0 | 32/0.21 | 0.60 | 2.80 | 19.50 | 12.0 |
| 1.50 | 30/0.26 | 0.60 | 3.10 | 13.30 | 16.0 |
| 2.50 | 50/0.26 | 0.70 | 3.80 | 7.98 | 22.0 |
| 4.0 | 56/0.31 | 0.80 | 4.40 | 4.95 | 29.0 |
| 6.0 | 84/0.31 | 0.80 | 5.20 | 3.30 | 37.0 |
| 10.0 | 80/0.41 | 1.00 | 6.80 | 1.91 | 49.0 |
| 16.0 | 126/0.41 | 1.00 | 7.20 | 1.21 | 76.0 |
| **Ambient temperature 40°C | ***Max. Operating temperature 70°C | |||||
Contact Details
-
5, Richmond Rd, Shanthala Nagar,
Ashok Nagar, Bengaluru, Karnataka - 560025 - 8884958881/080 4682 4685
- contact@gopalanmetals.com